Knowledge

Lexicon

Lorem ipsum dolor sit amet, consectetur adipiscing elit.
  • Electroniad

    Electronics quiz and championship, organized for the first time by Caeleste on 14 October 2016 in Technopolis, Mechelen. See electroniade.org .

  • Electronic shutter

    A method to operate an electronic image sensor in a way that the effective integration or exposure time (shutter time) is variable. The result is the same as that of the mechanical shutter found on the classical photo camera.

  • EM

    Electro-Magnetic radiation: Visible light is just one small part of the huge EM spectrum.

  • EMC

    Electro-Magnetic Compliance: the property to emit no (or little) radio wave EM radiation, or to be insensitive for spurious EM radiation or EMI.

  • EMCCD

    Electron-multiplying CCD.

  • EMI

    Electro-Magnetic Interference; various types of system level noise entering the IC via the air, IO wires and supply/ground wires.

  • EMVA

    European Machine Vision Association.

  • ENC

    Equivalent Noise Charge. Unit [electrons]. ENC=TN+FPN

  • Epi

    Epitaxial layer or wafer. Most CMOS image sensors need processing on highly doped wafers with on top a few microns thick "epitaxially grown? layer of lowly doped silicon.

  • Etaloning

    Interference pattern at the NIR side of the Silicon spectrum due to multiple reflections between the two parallel interfaces in (e.g.) a BSI wafer.

  • Excess noise

    Noise exceeding the theoretical PSN, as caused by electron and hole multiplication in Si, as in APD, SPAD or EMCCD.

  • Eye

    In many cases still the standard by definition in electronic vision. Giant imperfections conveniently hidden by the huge image correction engine behind it.

  • F-number

    Ratio between the opening (diameter) of the lens and its focal length. A high f-number means a large attenuation of the light power. A low f number is beneficial for low light imaging, but low f-numbers have also low depth of focus and are vulnerable to lens imperfections: sometimes written as f# or f/#.

  • FD

    Floating Diffusion. Circuit technique for the conversion of (photo) charge to a voltage, on a (not tied to a DC voltage, thus "floating") junction (junctions were historically created by impurity diffusion). Used in most CCDs and APSs. Invention attributed to Walter Kosonocky, but disputed to have been conceived already by Noble.

  • FEA

    Field Emission Array: Micro-machined silicon device that combines the light detecting mechanism of a Vidicon tube and the circuit possibilities of an integrated circuit.

  • FEE

    Front-end electronics. The driving electronics that reside close to the FPA.

  • FF

    Fill Factor: ratio [%] of the light sensitive area of a pixel on its total area. Should be quoted in conjunction with spectral response.

  • FF CCD

    Full Frame CCD: A FT CCD lacking storage area. Needs an external shutter.

  • f frame [Hz]

    f frame, Frame rate, the frequency at which frames are acquired.

  • firmware

    In almost all cases the configuration or upload of an FPGA.

  • Flux

    Light power per unit area [W/m2].

  • f Nyquist

    The Nyquist limit or ~frequency equals to the spatial frequency 1/(2 x pixel pitch) of a pixel array. Image information beyond this limit is "aliased" to lower spatial frequencies. In practice this aliasing appears as Moiré effects and color artifacts.

  • FPA

    Focal Plane Array. The image sensor as placed in the focal plane of a telescope.

  • FPN

    Fixed Pattern Noise, or spatial noise. Is the unwanted static (DC) variation of the response of all pixels in the image. Expressed as an offset in volts or in ADC bits.

  • FPNU

    Fixed pattern non-uniformity, identical to FPN, but this term makes it more explicit not to be "N" or temporal noise, conformant to PRNU and DSNU. Caeleste coined term.

  • Frame

    The electronic form of one image.

  • FT CCD

    Frame Transfer CCD.

  • G

    Gate, control terminal of a MOSFET. In a CCD the gates are called "electrodes".

  • gamma

    Response correction in cameras originally introduced to counteract the non-linear response of CRTs. The typical gamma correction takes the signal - or each of the R, G, B components - to the power of 0.45.

  • gamma rays

    see X-rays.